DigiSet Tire Inflator
TROUBLESHOOTING
Problem
Compressor does not
start/blows fuses.
Compressor runs but does
not inflate.
Compressor runs slowly.
Gauge appears to
read incorrectly or is
unreadable.
Display shows ERR
message.
5
by Wagan Tech
™
Solution
•
Push the power plug firmly into the DC socket
and twist it back and forth to ensure clean
contact.
•
Check DC socket for dirt and particles. Use a
non-conductive probe to clean the DC socket.
Do not use your fingers or metal.
•
Check vehicle lighter fuse; should be 15 amps
minimum.
•
Make sure the shutoff pressure setting is not
lower than the current pressure of the item you
are inflating.
•
Be sure the nozzle always touches the core of
the valve stem.
•
Check tire or other item being inflated for
leaks.
•
Check hose for breaks and leaks at fittings.
•
Overheated from excessive use. Shut it off and
let it cool for 15 minutes.
•
Voltage too low. Check condition of battery.
•
Disconnect valve connector from the tire. Press
and hold the "R" reset button until the display
shows all the digits and then returns to 0.0
www.wagan.com
®