Descargar Imprimir esta página

Champion Global Power Equipment 93001i-EU Manual Del Operador página 22

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 146
93001i-EU - 3000W PORTAbLE INvERTER GENERATOR
MAINTENANCE
Make certain that the generator is kept clean and stored properly.
Only operate the unit on a flat, level surface in a clean, dry
operating environment. DO NOT expose the unit to extreme
conditions, excessive dust, dirt, moisture or corrosive vapors.
Never operate a damaged or defective generator.
Your generator needs regular servicing and maintenance,
failure to properly maintain and service your generator
regularly will result in voiding any warranty. For clear guidance
read and understand this section.
For Emission control devices and systems, read and
understand your responsibilities for service as stated in the
Emission Control Warranty Statement of this manual.
The owner/operator is responsible for all periodic servicing and
maintenance.
Complete all scheduled maintenance in a timely manner.
Correct any issue before operating the generator.
For service or parts assistance, contact our
Technical Support Team at service@bpeholdings.co.uk.
Cleaning the Generator
DO NOT spray, jet, power wash generator directly with water.
Water can enter the generator through the cooling slots and
damage the generator windings. It can also contaminate the
fuel system.
1. Use a damp cloth to clean exterior surfaces of the generator.
2. Use a soft bristle brush to remove dirt and oil.
3. Use an air compressor (25 PSI) to clear dirt and debris from
the generator.
4. Inspect all air vents and cooling slots to ensure that they are
clean and unobstructed.
To prevent accidental starting, remove and ground the spark plug
wire before performing any service.
WARNING
WARNING
NOTICE
CAUTION
Changing the Engine Oil
Recommended every 100 hours or annually Change oil when the
engine is warm. Refer to the oil specification to select the proper
grade for your operating environment.
1. Set the generator on top of a work bench or table.
2. Loosen the four cover screws and remove the maintenance
cover
3. Remove oil fill cap/dipstick.
4. Tilt the generator on its side and allow the oil to drain
completely.
5. Add oil according to Add Engine Oil in Assembly section.
Recommended 10W30 DO NOT OVERFILL. Oil not included for
routine maintenance.
6. Reinstall the oil fill cap/dipstick and maintenance cover.
22
MAINTENANCE

Publicidad

loading