93001i-EU - 3000W PORTAbLE INvERTER GENERATOR
4. Remove the spark arrestor.
5. Carefully remove the carbon deposits from the spark arrestor
with a wire brush.
6. Replace the spark arrestor if it is damaged.
7. Position the spark arrestor on the muffler and attach the
spark arrestor and muffler cover by reversing the steps from
above.
Failure to clean the spark arrestor regularly will result in
degraded engine performance and may damage engine
resulting is voiding any warranty.
Federal and local laws and administrative requirements
indicate when and where spark arrestors are required. When
ordered, spark arrestors are required for operation of this
generator in National Forest lands. In California, this generator
must not be used on any forest-covered land, brush-covered
land, or grass-covered land unless the engine is equipped with
a spark arrestor.
Adjusting the Governor
Tampering with the factory set governor will void your
warranty.
The air-fuel mixture is not adjustable. Tampering with the governor
can damage your generator and your electrical devices and
will void your warranty. Contact our Technical Support Team at
service@bpeholdings.co.uk for all other service and/or adjustment
needs.
Maintenance Schedule
Follow the service intervals indicated in the following maintenance
schedule.
CAUTION
NOTICE
WARNING
Service your generator more frequently when operating in adverse
conditions.
Contact our Technical Support Team at service@bpeholdings.co.uk
to locate the nearest CPE certified service dealer for your
generator or engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE
Check oil level
Clean around air intake and muffler
FIRST 5 HOURS (BREAK IN)
Change oil
EVERY 50 HOURS OR ANNUALLY
Clean air filter
Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR ANNUALLY
Change oil
Clean/adjust spark plug
Clean spark arrestor
Clean fuel valve filter*
EVERY 250 HOURS
Clean combustion chamber*
Check/adjust valve clearance*
EVERY 3 YEARS
Replace fuel line*
* To be performed by knowledgeable, experienced owners or CPE certified service
centers.
STORAGE
To avoid accidental or unintended ignition of your generator
during periods of storage, the following precautions should be
followed:
– When storing the generator make sure the EZ Start dial is
set to the "STOP" position.
24
WARNING
STORAGE