USING
THE GENERATOR
System
Ground
The generator has a system ground that connects the
generator frame components to the ground terminals on
the AC output receptacles.The system ground is connected
to theAC neutral wire (the neutral is bonded to the
generator frame).
Special Requirements
There may be Federalor State Occupational Safety and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of the generator.
Pleaseconsult a qualified electrician, electrical inspector, o r
the localagency having jurisdiction.
• In some areas,generators are required to be registered
with local utility companies.
• If the generator is used at a construction site, there may
be additional regulations which must be observed.
Connecting
to a Building's
Electrical
System
Connections for standby power to a buitding's electrical
system must be made by a qualified electrician.The
connection must isolate the generator power from utility
power, and must comply with all applicable lawsand
electrical codes.
DANGER
When usinggenerator for backup power, notify utility
company. Use approved transfer equipment to isolate
generator from electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area,such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain.
DO NOT handle generator or electrical cords while standing
in water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
OPERATING
THE
G EN ERATO R
CAUTION
See"Don't Overload Generator" on page I I.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
Starting
the Engine
Disconnect alt electrical loadsfrom the generator. Use the
following start instruction steps by numerical order:
I.
Make sure unit is on a levelsurface.
IMPORTANT:
Failure to start and operate unit on a level
surface will cause the unit not to start or shut down during
operation.
2.
Turn the fuel valve to the "On" position (Figure 3).
Fuel Valve is shown
in the On position
3.
Follow start instructions given in engine owner's
manual.
NOTE:
If engine starts after 3 pulls but fails to run, or if
unit shuts down during operation,
make sure unit is on a
level surface and check for proper oil level in crankcase.
This unit may be equipped with a low oil protection
device.
See engine manual.
Connecting
Electrical
Loads
• Let engine stabilize and warm up for a few minutes after
starting.
• Plug in and turn on desired 120 and/or 240 VottAC,
single phase,60 Hz electrical loads.
/