R
Review
gas requirements
on back side of these instructions.
Remove
the pipe thread protective
cap.
Apply pipe joint compound
or about
1 1/2 wraps of Teflon tape over all threaded
connections.
NOTE:
Pipe joint compound
must be resistant
to the action of any liquefied
petroleum
gas.
Connect
the gas supply to the dryer. An additional
fitting is required to connect
the 3/4"
(1.9 cm) female thread
end of a flexible
connector
to the 318" (1 cm) male threaded
end
on the dryer.
Securely
tighten
the gas line fitting over threads.
Turn on the gas supply.
Check
all gas connections
for leaks using a soap solution.
If
bubbles
occur, tighten
the connections
and recheck.
DO NOT use an open
flame
to
check
for gas leaks.
Io 1
R
Review
electrical
requirements
on back side of these instructions.
BEFORE
OPERATING
OR TESTING,
follow the grounding
directions
on the reverse
side.
U.S. MODELS:
IMPORTANT-
All U.S. models
are produced
for a 3-WIRE
SYSTEM
CONNECTION.
The dryer frame is grounded
to the neutral
conductor
at the
terminal
block.
A 4-WIRE
SYSTEM
CONNECTION
is required
for new or
remodeled
construction,
mobile
homes,
or if local codes do not permit grounding
through
neutral.
If the 4-wire
system
is used, the dryer frame cannot be
grounded
to the neutral
conductor
at the terminal
block.
Refer to the following
instructions
for 3- and 4-WIRE
SYSTEM
CONNECTIONS.
Terminal
@/Block Cover
/ _ Plate _
/"% ,Y
"0
Remove
the terminal
block cover plate.
Insert the power cord with a U.L. listed strain relief through
the hole provided
in the cabinet near the
terminal
block.
NOTE:
a strain
relief
must
be used.
l 1,
q
Do not loosen the nuts already
installed
on the terminal
block.
Be sure they are tight.
Use a 3/8" (1 cm)
deep well socket.
3-WIRE
SYSTEM
CONNECTIONS
If the power cord has terminals,
place the terminals
over
the existing
nuts on the posts.
The neutral
(white or center
wire on power cord) conductor
must always
be connected
to the center (silver colored)
post of the terminal
block.
Secure
in place using the nuts provided
in the parts
package.
If the power
cord does not have terminals,
use
the cupped
washers
ahead of the nuts.
Be sure the terminal
block nuts are tight.
Secure the power
cord in position.
Tighten the strain relief screw(s)
in order to
clamp the strain relief to the cord.
Replace
the terminal
block cover.
WARNING:
If converting
from a 4-wire
electrical
system
to a 3-wire, the ground strap must be reconnected
to the
terminal
block support
to ground
the dryer frame to the
neutral
conductor.
Neutral
Post
3-Wire System
Ground
Strap
O
Neutral
Strain
relief