30. stoPPing and sHutting doWn
30.1 stoPPing
Turn the machine off by turning the switch to position "0" and unplug the power cable
from the outlet.

30.2 sHutting doWn

Once you have finished using the machine, disconnect it and clean it thoroughly.
Store it in a dry and safe place, protected against dust and damp.

30.3 routine maintenance

Follow the instructions given in the "STOPPING" section before you start to
work on the machine.
maintenance frequency
When the grinding wheel reaches a
minimum diameter of approximately
105 mm
40 hours

30.4 Handling and transPort

- If you need to transport the machine, take it off the bench or wall, dismantle the grind-
ing wheel and put all the parts in a packing box to protect them against impact.

30.5 demolition and disPosal

The machine is to be demolished by qualified personnel in compliance with current
laws in force in the country in which it is installed.
The symbol
(on the rating nameplate) points out that the product must not be
disposed of with normal household garbage. Contact an authorized technician or
your dealer for disposal instructions.
Before you scrap the machine, make it unusable by cutting the power supply
cable for example and make the parts safe. If not, this could cause a source
of danger for children if they should play with the machine.
31. trouble sHooting
Follow the instructions given in the "STOPPING" section before you start to
work on the machine.
Problem
Probable cause
One of the safety devices
of the system to which
the machine is connected
The machine fails to
has tripped (fuse, circuit
start when you switch on
breaker etc.)
(switch in pos. "1").
The machine is not plugged
into the outlet properly.
The grinder is not secured
correctly.
The arm-motor unit is not
secured correctly to the
base unit.
The machine vibrates
abnormally.
The vise assembly is not
secured correctly to the
base unit.
The grinding wheel is not
fitted correctly in its seat
on the hub.
- Contact a skilled technician if you are still unable to restore the correct operation
of the machine following the instructions given in the chart.
8 8
operation
Replace the grinding wheel.
Clean the grinder carefully using a rag or
a cleaning brush.
Clean the electric motor and the sliding
guides with caution.
Do not use compressed air.
solution
Reset the safety device.
If the safety switch trips
again, do not use the
machine, but contact a
skilled technician.
Unplug and plug in again
properly.
Check its attachment and,
if necessary, tighten the
securing screws correctly.
Tighten the related blocking
handle correctly.
Tighten the related blocking
handle correctly.
Dismantle the grinding
wheel, check its integrity
and fit again correctly.
en