Descargar Imprimir esta página

ccei RNS-1 Instrucciones De Uso página 13

Ocultar thumbs Ver también para RNS-1:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 41
OPERATING INS-
TRUCTIONS
3.1.1. Pump prohibition connection
3.1.1.1. To a CCEI brand electric box
The electric boxes manufactured by CCEI are fitted with a pre-connected terminal block marked
ABCD for automatic level regulators.
• A and B: filtration pump forced operation (not used for RNS-1, RNS-2 and NIVA 3 Module)
• C and D: pump prohibition
All that remains to do is to remove the "shunt" between C and D on the filtration box and to connect
the 2 wires from the "Pump prohibition" output of the RNS-1, RNS-2 and NIVA 3 Module box
instead.
3.1.1.2. On a standard electric box
If the electric box is not pre-fitted for automatic level regulation, connect directly to the filtration
contact . The following information is given as an indication only. It is imperative to follow the
instructions for your pool electric box or to first contact your box manufacturer.
Pump prohibition:
Connect the Pump prohibition terminal block to terminal block A1 on the filtration contact
• A: existing wires in the filtration box
• B: filtration contact installed in the box
• C: wire to add to connect the pump prohibition to the box RNS-1, RNS-2 and NIVA 3 Module
Disconnect the wire or wires arriving on the A1 terminal block from the filtration contact and send
them to a terminal on the "Pump prohibition" screw terminal on the RNS-1, RNS-2 and NIVA
3 Module box. Then use another wire to connect the other "Pump prohibition" screw terminal to
terminal A1 on the filtration contact.
RNS-1, RNS-2 and NIVA 3 Module
v1.0EN
5

Publicidad

loading

Este manual también es adecuado para:

Rns-2Niva 3Pf10l006Pf10l002Pf10l009