Overview And Use; System Safety; Closing Valve For Water Supply; Closing Valve For Air Supply - Ecolab Cerberus Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Overview and Use

The Cerberus unit is complete hygienic and disinfec-
tor station for use in doorways between food areas.
It is activated by a pre-programmed timer and/or a
motion sensor. The nozzle system sprays a mixture of
water and detergent / disinfectant on the floor in the
doorway when needed.
Consumptions:
The unit is approved for the use of detergents and
disinfectants.
Warning: Do not change the settings
made or recommended by the supplier
of the detergents!
Detergents are supplied via separate standard cans.
Before installation and set up of the unit always read
this instruction thoroughly. Always make sure to
follow personal saftey procedures for chemicals in
connection with refilling procedures (product change),
maintenance and repair. See also product label and
MSDS sheet.
Safety instructions
Only professional service personel are allowed to
carry out service and repairs on the unit.
Only instructed personel are allowed to operate the
unit.

5. System Safety

In case of error/defect or service on equipment:
1. close the water supply
2. close the air supply

5.1. Closing valve for water supply.

With this valve the unit can be isolated from the water
supply. Further, a non-return valve is built in the block
to prevent backflow of water.

5.2. Closing valve for air supply.

Open
Fig 1
With this valve the unit can be isolated from the air
supply. The non-return valve for air is built in the unit
to prevent backflow of air.
Fig 2

5.3. Anticipated failures

Bursted air tube in unit:
• The unit must never be used without the front
cover being mounted.
• The air closing valve on /in connection with the
unit must always be closed when not in use.
• Air tube and fitting should be examined regularly
and exchanged in case of visible damages.
Breakdown of non-return valves for air and water:
• The unit must never be used without the cover be-
ing mounted.
• Air and water closing valve on/in connection with
the unit must always be closed when the unit is
Closed
not in use.
• After use of the unit all chemical non-return valves
must be thorougly rinsed with clean water. Follow
instructions in paragraph 9.2.
• Non-return valves for air and water should be
examined minimum once a year by authorised
personel for defects.
110003759
Open
The air pressure regulation/gauge only
works when the supply valve is open,
and the unit is active.
Wear glasses when using the unit.
Wear gloves and suitable clothing
when using the unit.
Closed
110003760
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

110003423

Tabla de contenido