Auto to Manual Conversion
Jackets with the Mark 5i firing system can be fitted with blanking caps to allow easy conversion from
automatic inflation to manual only inflation. To convert the jacket unzip the cover to allow access to the
cylinder and firing head.
Convert the cylinder and ensure it's
full and has not been pierced before
screwing back in, hand tight.
Take a TeamO blanking cap and fit it to the
firing head, hand tighten over the automatic
capsule. Re-pack the jacket in accordance
with the packing instructions.
The automatic capsule indicator identifies the
CO
cylinder status. Red indicates that it is
2
missing or has been pierced.
Check the status of your jacket before use.
Servicing your TeamO Lifejacket
Service your jacket every 2 years (minimum), at an authorised station to retain your warranty. An annual
service by an authorised service station is highly recommended.
For professional frequent and extreme use we recommend a full service annually from date of purchase
and within the automatic capsule expiry date. For leisure users 2 years full service from the date of
purchase and within the capsule expiry date.
NOTE! Lifejacket should be serviced at a service station accredited by the manufacturer within one
month either side of the service date. Visit www.teamomarine.com for details about servicing
WARNING! Gas cylinders are dangerous and must be kept away
from children and never misused.
Pull Toggle
Automatic
Capsule Indicator
TEAMOMARINE.COM
Manual
Deployment
Indicator
Sealing Cap
38g CO
2
170N Jacket
5