ENGLISH
Note:
It is normal for there to be an unusual odour when switching on the appliance for the first time.
Leave the appliance running in a well-ventilated room for 2 to 3 hours.
Unwind the power cord completely and inspect it for damage. Do not use the appliance if it or
its cord have been damaged or are not working properly.
Make sure you have read and understood all instructions and warnings in this instruction
manual. Pay particular attention to the safety instructions on previous pages.
3. PRODUCT INSTALLATION
The device can be installed either on the floor or on the wall (feet and mounting brackets
included).
The heater operates on natural-air convection. For optimum performance and even heat
distribution, when installing the heating appliance on the wall or floor, you should allow at
least 20 cm clearance to the
sides,
50 cm clearance above the top, and 20 cm clearance from
any walls or objects (furniture, curtains, etc.). In addition, if wall-mounted, the bottom of the
heater must be at least 20 cm from the floor.
Wall assembly
Table 1. Reference distances by model for installation (Fig. 2)
Reference:
Models
05330
Ready Warm 800 Thermal
Ready Warm 1200
05331
Thermal
Ready Warm 1800
05332
Thermal
Ready Warm 2000
05333
Thermal
Ready Warm 2500
05334
Thermal
1.
Before installation, make sure the appliance complies with the safety distances
mentioned above.
2.
Drill 2 holes on the wall with specific distance between them according to the following
table (Fig. 3):
READY WARM 800/1200/1800/2000/2500 THERMAL
48
a (mm)
b (mm)
e (mm)
410
93
140
550
93
280
690
93
420
830
93
560
970
93
695
05330
ReadyWarm
800 Thermal
140mm
3.
Attach the wall supports (5) to the wall using the studs and screws provided. Make sure
the part of the bracket with the smallest diameter is the one attached to the wall. Fig. 4
4.
Screw the wall-support accessory (6) to the 2 holes at the bottom rear of the appliance.
Make sure the side with just 1 hole is facing the wall. Fig. 5
5.
Hang the appliance from the wall brackets (5). Fig. 6
6.
Once hung on the wall, mark the free hole of the wall-support accessory (6).
7.
Remove the appliance from the wall, drill a hole where the mark is, and insert the
corresponding stud.
8.
Finally, hang the device on the wall brackets (5) and screw the wall-support accessory to
the wall. Fig. 7
Assembly on floor Fig. 8
Place the stand on the bottom part of the device, each one on one side, and screw them. Make
sure they are properly fixed.
4. OPERATION
Automatic lock
f (mm)
The buttons on the device's control panel will block if no button is pressed for 1 minute during
495
operation. The lock indicator will light up on the display.
To unlock the control panel, press the decrease button for 3 seconds.
495
The radiator can be used manually or can be programmed.
495
Manual mode
3 operating modes:
495
-
Day mode: the temperature can be adjusted from 5 ºC to 35 ºC.
-
Sleep mode: the temperature can be adjusted from 5 ºC to 35 ºC.
495
-
Anti-frost mode: the temperature can be adjusted from 5 ºC to 15 ºC.
Warnings:
For the device to be able to operate, the set temperature must always be higher than the room
one. The panel will display the room temperature. As the temperature shown on the display is
05331
05332
05333
ReadyWarm
ReadyWarm
ReadyWarm
1200 Thermal
1500 Thermal
2000 Thermal
280mm
420mm
560mm
READY WARM 800/1200/1800/2000/2500 THERMAL
ENGLISH
05334
ReadyWarm
2500 Thermal
695mm
49