Introduction of Operating
Temperature control range: - 20 ℃ ~ 20 ℃
Standard voltage input range: DC 12V / 24V, maximum not exceeding DC 30V
1. Refrigerator opening and closing
Connect the correct DC 12 / 24 V power supply. If the refrigerator is in standby mode, the
"---" symbol will be displayed in the middle of the display screen after the refrigerator comple
tes the self-test. At this time, long press the on / off button for 2 seconds to complete the start
-up. After the start-up, the display screen will normally display the current temperature
in the container, working mode and other characters. After the start-up delay (1 minute preset
from the factory), the refrigerator works in the working mode, and the compressor starts to
work for refrigeration. To turn off the refrigerator, press the on / off button for 3 seconds while
the control panel is unlocked.
2. Refrigerator control panel locking and unlocking
If the control panel is locked (the child lock icon in the lower right corner of the display is on),
press and hold the "up / down" button for 3 seconds at the same time to release the lock. If
there is no operation for 20 seconds, it will automatically enter the control panel lock state.
3. Set the refrigerator temperature
When the control panel is unlocked, press the "up / down" key to adjust the temperature rise
or fall of the refrigerator (a group of temperature values on the display screen flicker to display
the current setting value. Each time you press the button, the temperature rises or falls by 1
degree. If you hold the button, you can quickly adjust to the desired temperature value. If the
re is no change within 5 seconds, the setting value will be saved automatically.
4. Set the compressor working mode
When the control panel is unlocked, press the "set" button to freely switch the compressor w
orking mode "Eco / Max". If you need to cool down to a lower temperature quickly, you can u
se the "MAX" mode. If you only need to use the refrigeration or heat preservation function, y
ou can set it to the "ECO" mode to save energy and power.
5. Set the low voltage protection function
This product has the function of low voltage protection. When it detects that the battery volta
ge is lower than the set value, it will automatically turn off the compressor to prevent over dis
charge from damaging the battery or causing the car unable to start normally. At this time, th
e screen will display "E1" code prompt. If the voltage returns to normal, the refrigerator will
automatically enter the working state one minute later. The factory default is "Medium". If you
need to change it, please follow the following steps:
a: Unlock control panel.
b: Long press the "set" button for 3 seconds, release it after hearing the buzzer "Di", and then
press the "set" button one time. At this time, one of the battery protection level icons "L, M, H"
on the display will flash, and then press the "up / down" button to change the setting.
Specific value refer to the table below:
Battery protection
12 V turn off
Low grade - L
9.6 V
Medium - M
10. 4 V
High grade-H
11.1 V
WARNING!
1.If your refrigerator enters the battery protection in advance, it may be because your po
wer supply voltage is insufficient and the low voltage protection value is set too high, or
your DC power supply wiring is improper and cannot provide enough current. Check whe
ther the power supply wiring is appropriate, and consider appropriately lowering the batte
ry protection gear.
2.In order not to affect the normal start of the car, it is recommended to set the protection
level at "H"when using the refrigerator on the car.
6. Single and double temperature zone function
This product has the function of automatically identifying the temperature zone. Inserting the
middle partition, the default is double temperature zone. The left zone is the freezing zone, a
nd the right zone is the refrigeration zone. At this time, the temperature of the freezing zone
can be adjusted. Remove the middle partition as a single temperature zone, and the tempera
ture is subject to the actual set value.
Cleaning and Maintenance
Before cleaning, it is necessary to disconnect the power supply, and wipe the inner and outer
surfaces of the refrigerator with a cleaning cloth dipped with an appropriate amount of water
or detergent. It is not allowed to wash with water directly to avoid damaging electrical compo
nents.
When the refrigerator is not used for a long time, it is necessary to clean the inside and outsi
de of the refrigerator and keep it dry, and take moisture-proof and dust-proof measures to av
oid mildew and peculiar smell inside the refrigerator.
Error Code Description
When the compressor, module, fan and temperature sensor are abnormal and the input volt
age is too low, the error code will appear on the display screen, and the compressor will stop
working. After the abnormality is eliminated, unplug the power supply and plug it in again, the
temperature in the refrigerator can be displayed normally, and the compressor cooling mode
will start to work after 1 minute.
12 V Turn on
24 V turn off
24 V Turn on
10.9 V
21.3 V
22.7 V
11. 7 V
22.8 V
24.2 V
12.4 V
24.3 V
25.7 V