If the room temperature is lower than the required value, it is advisable to set a higher order curve and vice versa. Pro-
ceed by increasing or decreasing in steps of one and check the result in the room.
90
85
80
70
60
50
40
30
20
20
fig. 14- Compensation curves
Adjustments from Remote Timer Control
If the boiler is connected to the Remote Timer Control (optional), the previously described adjustments are
A
managed as described in table 1.
Table 1
Heating temperature adjustment
DHW temperature adjustment
Summer/Winter Switchover
Eco/Comfort selection
Sliding Temperature
EN
10
9
8
7
10
0
-10
Adjustment can be made from the Remote Timer Control menu and the boiler control panel.
Adjustment can be made from the Remote Timer Control menu and the boiler control panel.
Summer mode has priority over a possible Remote Timer Control heating demand.
On disabling DHW from the Remote Timer Control menu, the boiler selects Economy mode. In this
condition, the eco/comfort button on the boiler panel is disabled.
By enabling DHW from the Remote Timer Control menu, the boiler selects Comfort mode. In this
condition it is possible select one of the two modes on the boiler panel.
You can make all the adjustments by using the remote timer control.
cod. 3541C662 - Rev. 00 - 09/2020
OFFSET = 20
6
90
85
5
80
70
4
60
50
3
40
30
2
20
1
OFFSET = 40
90
85
80
70
60
-20
50
40
30
20
fig. 15- Example of compensation parallel
10
9
8
7
6
5
4
3
2
1
10
9
8
7
6
5
4
3
2
1
curve offset