Service
- Troubleshooting - Fault diagnosis menu
Fault diagnosis menu.
To access the fault diagnosis menu, press any button when the burner is ready to operate, when the burner is in
operation, or when it is in malfunction mode. It is not possible to access the fault diagnosis menu during the start-
up phase. The general menu screen will appear. Using the buttons
diagnosis menu symbol, and confirm using the button .
The details of the last fault to appear are indicated by the flashing symbol. The flame intensity, network voltage,
air flap position, number of burner start-ups as well as the operating time of the burner at the time it switched to
malfunction mode are displayed underneath.
Using the buttons
number is displayed in the upper left corner of the display). After the details of the last 5 faults, the telephone
number of the after-sales department as well as the maintenance contract number are shown (no values are
entered in the factory).
• Quit the menu using the button
Entering a telephone number for the maintenance company and the maintenance contract number.
When the corresponding symbol appears on the display:
• Keep the button
• Using the buttons
• Using the button
• When the number is complete, save using the button
420010562400
and
, it is possible to call up the details of the last 5 faults to have appeared (the fault
.
held down until the first figure starts to flash (a short press will exit the menu).
or
, change the figure to the value required (underscore = empty field)
move on to the next figure.
,
,
, or
, place the cursor on the fault
.
www.ecoflam-burners.com
EN
23