ACDelco ANG201 Manual Información Del Producto página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. Shut-off Valve
1
NOTE
all hoses and fittings are of the recommended size and be sure the tool is not used
with more than or less than the recommended pressure at the tool!
PARTS AND MAINTENANCE INFORMATION
The use of other than genuine ACDelco Tools replacement parts may result in
safety hazards, decreased tool performance and increased maintenance, and
may invalidate all warranties.
Repairs should be made only by authorized trained personnel. Consult your
nearest ACDelco Tools Authorized Service Center.
When the life of the tool (these tools) has expired, it is recommended that the
tool (these tools) be disassembled, degreased and parts be separated by material
so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized
Service Center.
Refer all communications to the nearest ACDelco Tools Distributor.
Proper lubrication of this air tool (these tools) is critical to the operation and life of the
unit. Units can be severely damaged or have excessive wear placed on working parts if
not lubricated. Always use an air line lubricator with the tool (these tools). After each
eight hours of operation, detach the air hose and inject about 1.5 c.c. of oil into the inlet
bushing. If this tool is equipped with an impact mechanism, remove the oil chamber
1English1
8. Drain
7
5
8
Always use clean, dry air as excessive moisture will lower the
available torque and rust the interior moving parts. Make sure
MAINTENANCE
CAUTION
LUBRICATION
English
9. Drain
3
2
9
-6
6
to Air Tool
4

Publicidad

Tabla de contenido
loading

Tabla de contenido