Programming
ON
MENU
PRE-
STANDBY
A B C
HEAT
Programming Pads (1–8)
Pads (1–8) activate a programmed cooking
sequence when pressed. Program each pad
individually to form menus. Programming
remains in memory until reprogrammed.
Programming Mode
1. Verify oven shows "READY" in display.
• If oven display shows "STANDBY",
press ON/STANDBY pad.
• If "R" in "READY" is not flashing, open and
close oven door.
• Preheat temperature and "PREHEAT"
appear in display if oven is in preheat
mode.
2. Open oven door. Oven door must remain
open during programming.
3. Press and hold 1 pad for approximately 3-5
seconds.
SELECT MENU AND PAD
A PAD ?
Current Menu
4. Press MENU A B C pad, if necessary, to
select menu.
5. Press desired (1–8) pad.
SELECT COOK FUNCTION
A PAD 1
STAGE 1
Current Menu
6. Press MICROWAVE, CONVECTION, or
COMBINATION pad to select cooking
function.
7. Set time, temperature, and/or power levels.
• If MICROWAVE pad is chosen, see
Manual Microwave Entry steps 3–6.
• If CONVECTION pad is chosen, see
Manual Convection Entry steps 4–7.
• If COMBINATION pad is chosen, see
Manual Combination Entry steps 4–9.
MICROWAVE CONVECTION COMBINATION
8. Press OPTION pad after setting time,
temperature, and/or power levels to
advance to next stage.
• Repeat steps 4–6 up to 4 times to
create a maximum of 4 cooking stages.
If no additional cooking stages are
required, go to next step.
SELECT COOK FUNCTION
Current Menu
9. Press START pad to save cooking
sequences. Oven display shows
"SELECT MENU AND PAD" and
"(A, B, or C) PAD ?".
• Repeat steps 4-8 to program additional
pads.
10. Close oven door to exit programming
mode.
Summary of Programming Preset Pads
1. Open oven door.
2. Press and hold "1" pad.
3. Press MENU A B C pad to select menu.
4. Press (1–8) pad to be programmed.
5. Press MICROWAVE, CONVECTION, or
COMBINATION pad.
6. Set time, temperature, and microwave power level
according to instructions.
7. Press OPTION pad to set second stage or START pad
to save entry. Repeat 4-8 to program additional pads.
8. Close oven door.
16
OPTION
A PAD 1
STAGE 2
START
1
2
3
4
5
6
7
8
STOP
RESET