6
Switch on/off Seasonal Flow Control (SFC).
• The SFC function optimises the pump speed and with it the water volume and pumping head
based on the water temperature.
7
Control system connection
• The control system makes it possible to regulate the pump power.
Hose sleeve ∅ 50 mm
• Without the control system, the pump runs permanently at full power.
Hose sleeve ∅ 38 mm
8
9
• Alternative for outlet AquaMax Eco Expert 21000 and 26000.
10
Hose clips for fastening hoses on the hose sleeves.
Installation variants
A
• Variant (a): Submerged pump installation
– The pump is positioned in the pond or basin.
– Water flow via the filter cage.
• Variant (b): Dry pump installation
– The pump is installed without the filter cage outside of the pond or basin but lower than the
water level.
– Water flow via a satellite filter or skimmer.
Installation and connection
The pump can be installed submerged (in water) or dry (outside the water).
The use of the pump is only permitted with observance of the specified water quality.
• Pool water or salt water can impair the appearance of the unit. Such impairments are excluded
from the guarantee.
WARNING
Severe injuries or death due to operation of this unit in a swimming pond. Defective electrical
components will electrify the water with dangerous electrical voltage.
Never operate the unit in a swimming pond.
CAUTION
Rotating components in the intake and pressure socket area. Risk of injury when reaching into
the sockets.
In particular, observe the following: A unit that has stopped due to overload can start up unex-
pectedly!
Do not reach into the opening of the intake socket or pressure socket while the power plug is
plugged in.
If the sockets are freely accessible during operation, e.g. if no hoses are connected, use a hand
guard to secure the sockets. The hand guard is available as an accessory.
12