Descargar Imprimir esta página

Candy OCGF12B Manual De Instrucciones página 16

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 83
GB
For natural gas connection;
Main Gas Pipe
Gasket
Nut
Natural Gas
Connection Hose
Ventilation Of Room
The air needed for burning is received from room air and the gases emitted
are given directly in room. For safe operation of your product, good room
ventilation is a precondition. If no window or room to be utilized for room
ventilation is available, additional ventilation should be installed. However,
room has a door opening outside, it is no needed to vent holes.
Smaller than 5 m³
Between 5 m³ - 10 m³
Bigger than 10 m³
In basement or cellar
Room size
WARNING: Natural gas connection should
be done by authorized service.
For natural gas connection, place gasket
in the nut at the edge of natural gas connection
hose. To install the hose on main gas pipe,
turn the nut. Complete the connection by
making gas leakage control.
16
Ventilating opening
min. 100 cm²
min. 50 cm²
No need
min. 65 cm²

Publicidad

loading