Cell in poor condition
Battery cell(s) damaged or short-circuited, replace the battery as soon as possible.
Recharge - Retest
Battery is not stable, recharge and retest to avoid any possible errors.
If the test result is the same after charging and retesting, the battery should be considered defective and
Press the
Internal resistance
Starting current
entered [Car].
Battery reference ente-
red [Motorcycle]
Translation of the original
instructions
0%
SOH
BAD CELL
R:
99.99
STD:
300 A
4%
SOH
CHARGE-RETEST
R:
34.96
STD:
400 A
must be replaced.
keys to view SOH (State of Health) or SOC (State of Charge).
100%
SOH
GOOD BATTERY
R:
4.48
STD:
500 A
96%
SOC
GOOD BATTERY
R:
4.48
STD:
12N9-4B-1
CCA :
10 A
VOL:
7.89 V
CCA :
86 A
VOL:
11.95 V
SOH (state of health of
the battery)
CCA :
670 A
Calculated starting
current
VOL:
12.54 V
SOC (state of charge of
the battery)
CCA :
670 A
VOL:
12.54 V