Descargar Imprimir esta página

Craftsman Evolv 921.167500 Manual Del Operador página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
& Assembly
The air compressor
should
be turned
off, unplugged
from the power source, the air bled from the tank and
the unit allowed
time to cool before any maintenance
is performed.
Personal
injuries
could
occur
from
moving
parts,
electrical
sources,
compressed
air or
hot surfaces.
The quick
connect
assembly
must
be
attached
before
use. Failure
to assemble
correctly
could
result in leaks and possible
injury. If unsure
of
assembly
instructions
or you experience
difficulty
in
the assembly
please call your local service department
for further
information.
Getting
Started = Location
of the Air Compressor
The air compressor
should
always
be located
in a
clean, dry and well ventilated
environment.
The unit
should
have at
minimum,
12 inches of space on each
side. The air filter intake should
be free of any debris
or obstructions.
Check the air filter
on a daily
basis to make sure it is
clean and in working
order.
Risk Of Fire Or Explosion
This product
incorporates
snap action switch contacts
and a universal
electric
motor which tend to produce
arcs
and
sparking
and
therefore
should
not
be
exposed
to flammable
liquids or vapors.
This product
is not intended
for installation
or use in a commercial
garage
or shop environment.
Grounding
instructions
This product
must
be grounded.
In the event of an
electrical
short
circuit,
grounding
reduces
the
risk
of electric
shock by providing
an escape wire for the
electric
current.
This
product
is equipped
with
a cord
having
a
grounding
wire with an appropriate
grounding
plug.
(See the figure
below.)
The plug
must
be plugged
into an outlet
that is properly
installed
and grounded
in accordance
with
all local codes
and ordinances.
Check with a qualified
electrician
or service
personnel
if these instructions
are not completely
understood
or if in doubt
as to whether
the
tool
is properly
grounded.
......
i_
Grounded
Out/et
Grounding
Pin
._
Improper
installation
of the grounding
plug will result
in a risk of electric
shock.
If repair
or replacement
of the
cord
or plug
is necessary,
do not
connect
the
grounding
wire
to
either
flat
blade
terminal.
The
wire
with
insulation
having
an outer
surface
that
is green
with
or without
yellow
stripes
is the
grounding
wire.
Check
with
a qualified
electrician
or serviceman
if the grounding
instructions
are not
completely
understood,
or if in doubt
as to whether
the product
is properly
grounded.
Do not modify
the
plug provided.
If it will not fit the outlet, havethe
proper outlet installed
by a qualified
electrician.
This product
is for use on a circuit
having
a nominal
rating
of 120 volts
and
is factory-equipped
with
a
specific
electric
cord and plug to permit
connection
to a proper
electric
circuit.
Hake sure the product
is
connected
to an outlet
having the same configuration
as the plug. An adapter
should
not be used with this
product.
If the product
must be reconnected
for use
on a different
type of electric
circuit,
qualified
service
personnel
should
make the reconnection.
Extension Cords
Use only a 3-wire
extension
cord that has a 3-blade
grounding
plug
and
a 3-slot
receptacle
that
will
accept
the
plug
on the
product.
Hake
sure
your
extension
cord
is in good
condition.
When
using an
extension
cord,
be sure to use one heavy
enough
to carry
the current
your
product
will
draw. Cords
must not exceed
25 feet and No. 12 AWG size must
be used. An undersized
cord will cause a drop in line
voltage
resulting
in loss of power
and overheating.
Break In Procedures
No break in procedure
is required
by the user.
This
product
is factory
tested
to
ensure
proper
operation
and performance.

Publicidad