Descargar Imprimir esta página

Craftsman Evolv 921.167500 Manual Del Operador página 8

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance
NOTE: Any service
procedure
not covered
in the
maintenance
schedule
should
be performed
by
qualified
service
personnel.
The air compressor
should
be turned
off, unplugged
from
the power
source,
air bled from
the tank and
allowed
time to cool before
any maintenance
is per-
formed..
To ensure efficient
operation
and longer
life of
the air compressor
unit, a routine
maintenance
schedule
should
be followed.
The following
schedule
is geared toward
a consumer
whose
compressor
is
used in a normal
working
environment
on a daily
basis.
items
to Check/Change
Check Tank Safety Valve
Check and Clean Air Filter
Overall Unit Visual Check
Drain Tank
Check Power Cord for
Damage
Before each use
or daily
x
x
x
x
X
Do not attempt
to tamper
with the tank safety
valve. Anything
loosened
from this device could fly
up and hit you. Failure to heed this warning
could
result in death
or serious
personal
injury.
If air leaks after the ring has been released,
or if the
valve is stuck and cannot
be actuated
by the ring,
do not use the air compressor
until the tank safety
valve has been replaced.
Use of the air compressor
in this condition
could
result in serious
personal
injury.
TANK SAFETY VALVE
TO RELEASE AIR
RiNG
To check or replace
air filter element,
1. Press in on air filter cap while
rotating
counter-
clockwise
to remove filter cap.
2. Remove
air filter element
for visual inspection.
Loose debris
or minor dust may be removed
with
a soft bristle
brush or compressed
air. Filter
element
should
be replaced
if it is wet, torn or
satu rated.
5. Wipe clean the inside of the filter
housing
before
replacing
air filter.
Check the Tank Safety Valve by performing
these
steps:
The tank safety valve will automatically
release
air if the air receiver
pressure
exceeds
the preset
maximum.
The valve should
be checked
before
each day of use by pulling
the ring by hand.
1. Turn the air compressor
on and allow the tank to
fill. The compressor
will shut off when the
pressure
reaches the preset
maximum.
2. Turn the air compressor
off.
3. Pull the ring on the tank safety valve to release
air for three to five seconds.
4. Release the ring. Air must immediately
stop
escaping
when the ring is released.
Any continued
loss of air after releasing
the ring
indicates
a problem
with the tank safety valve.
Discontinue
use and seek service
before
continued
use of the air compressor.

Publicidad

loading