2. Operation
2.10. Function selection of remote controller
The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when
needed.
Item 1
1. Change Language
Language setting to display
("CHANGE LANGUAGE")
2. Function limit
(1) Operation function limit setting (operation lock)
("FUNCTION
SELEC-
TION")
(2) Use of automatic mode setting ("SELECT AUTO
(3) Temperature range limit setting ("LIMIT TEMP
3. Mode selection
(1) Remote controller main/sub setting ("CON-
("MODE SELECTION")
(2) Use of clock setting ("CLOCK")
(3) Timer function setting ("WEEKLY TIMER")
(4) Contact number setting for error situation
(1) Temperature display °C/°F setting ("TEMP
4. Display change
("DISP MODE SETTING")
(2) Suction air temperature display setting ("ROOM
(3) Automatic cooling/heating display setting
2.10.1. Function selection flowchart
[1] Stop the air conditioner to start remote controller function selection mode. → [2] Select from item 1. → [3] Select from item 2. → [4] Make the setting. (Details are specified
in item 3) → [5] Setting completed. → [6] Change the display to the normal one. (End)
Normal display (Display when
the air condition is not running)
(Hold down the E button and press the D button for two
seconds.)
* The display cannot be changed during the unit function
selection, the test run and the self diagnosis.
Item 1
Press the G button.
Change Language
("CHANGE LANGUAGE")
Press the
→ Operation function limit setting ("LOCKING FUNCTION")
E button.
Function limit
("FUNCTION
Press the
SELECTION")
G button.
Press the
Press the
E button.
E button.
→ Remote controller main/sub setting ("CONTROLLER MAIN/SUB")
Press the
G button.
Mode selection
("MODE
SELECTION")
Press the
E button.
→ Temperature display °C/°F setting ("TEMP MODE °C/°F")
Press the
Display change
G button.
("DISP MODE
SETTING")
Item 2
("LOCKING FUNCTION")
MODE")
FUNCTION")
TROLLER MAIN/SUB")
("CALL.")
MODE °C/°F")
TEMP DISP SELECT")
("AUTO MODE DISP C/H")
Remote Controller Function Se-
lection Mode
Item 2
Press the G button.
Use of automatic mode setting ("SELECT AUTO MODE")
Temperature range limit setting ("LIMIT TEMP FUNCTION")
Press the G button.
Use of clock setting ("CLOCK")
Timer function setting ("WEEKLY TIMER")
Contact number setting for error situation ("CALL.")
Press the G button.
Suction air temperature display setting ("ROOM TEMP DISP SELECT")
Automatic cooling/heating display setting ("AUTO MODE DISP C/H")
Item 3 (Setting content)
Display in multiple languages is possible.
Setting the range of operation limit (operation lock)
Setting the use or non-use of "automatic" operation mode
Setting the temperature adjustable range (maximum, minimum)
Selecting main or sub remote controller
* When two remote controllers are connected to one group, one
controller must be set to sub.
Setting the use or non-use of clock function
Setting the timer type
Contact number display in case of error
Setting the telephone number
Setting the temperature unit (°C or °F) to display
Setting the use or non-use of the display of indoor (suction) air
temperature
Setting the use or non-use of the display of "Cooling" or "Heat-
ing" display during operation with automatic mode
(Hold down the E button and press
the D button for two seconds.)
* The remote controller records the
setting that is made in this way.
See [4]–1
Item 3
(Setting content)
See [4]–2. (1)
Press the
D button.
See [4]–2. (2)
See [4]–2. (3)
Press the
D button.
See [4]–3. (1)
See [4]–3. (2)
See [4]–3. (3)
See [4]–3. (4)
Press the
D button.
See [4]–4. (1)
See [4]–4. (2)
See [4]–4. (3)
NOTE
Timer operation stops when the display for
remote controller function selection is
changed to the normal one.
Dot display
The language that is selected in
CHANGE LANGUAGE mode ap-
pears on this display. English is
set in this manual.
F
TEMP.
ON/OFF
MENU
ON/OFF
FILTER
E
BACK
MONITOR/SET
DAY
CHECK
TEST
PAR-21MAA
CLOCK
OPERATION
CLEAR
G
C
D