Descargar Imprimir esta página

Huawei GT 4 Guia De Inicio Rapido página 5

Publicidad

Frequency bands and power
(a) Frequency bands in which the radio equipment operates: Some bands may not be available in all countries or all areas. Please contact the local carrier
for more details.
(b) Maximum radio-frequency power transmitted in the frequency bands in which the radio equipment operates: The maximum power for all bands is less
than the highest limit value specified in the related Harmonized Standard.
The frequency bands and transmitting power (radiated and/or conducted) nominal limits applicable to this radio equipment are as follows: Wi-Fi 2.4G: 16.5
dBm, Bluetooth 2.4GHz: 14 dBm, NFC 13.56MHz:42 dBμA/m at 10m, Watch Wireless Charger:110.5-119KHz: 42dBμA/m at 10m, 119-135KHz: 66
descending 10 dB/dec above 119KHz at 10m, 135-140KHz: 42dBμA/m at 10m, 140-148KHz: 37.7dBμA/m at 10m.
Accessories and Software Information
It is recommended that the following accessories should be used:
Charging cradle:CW04
The product software version is 3.1.2.21(SP1C00M00)
Software updates will be released by the manufacturer to fix bugs or enhance functions after the product has been released. All software versions released
by the manufacturer have been verified and are still compliant with the related rules.
All RF parameters (for example, frequency range and output power) are not accessible to the user, and cannot be changed by the user.
For the most recent information about accessories and software, please see the DoC (Declaration of Conformity) at
https://consumer.huawei.com/certification.
Please visit https://consumer.huawei.com/en/support/hotline for recently updated hotline and email address in your country or region.
Please go to Settings > About > Regulatory information on the device to view the E-label screen.
ISED Canada compliance
RF exposure requirements
Important safety information regarding radio frequency (RF) radiation exposure:
The device complies with RF specifications when the device is worn on the wrist and at a distance of 1.0 cm from your face. Failure to observe this
guideline may result in RF exposure exceeding limits.
When using the wireless power charging function, this equipment should be operated with a minimum distance of 10 cm between the device and your
body.
Certification information (SAR)
This device is also designed to meet the requirements for exposure to radio waves established by Innovation, Science and Economic Development
Canada (ISED).
The SAR limit adopted by Canada is 1.6W/kg averaged over 1 gram of tissue for use against the head and 4.0W/kg averaged over 10 grams of tissue for
use on the wrist, and the highest SAR value reported to the ISED for this device type complies with this limit.
ISED Statement
This device complies with CAN ICES-3 (B)/NMB-3(B).
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licenceexempt
RSS(s). Operation is subject to the following two conditions: 1) This device may not cause interference. (2) This device must accept any interference,
including interference that may cause undesired operation of the device.
3

Publicidad

loading

Este manual también es adecuado para:

Pnx-b19