Descargar Imprimir esta página

Xetron STC-1000Pro Manual De Uso página 6

Controlador de temperatura inteligente

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

2.3 Parameter Viewing
Press
or
to enter
Press
to view the parameters and relative values in ascending order:
TS→CD→HD→PT→AH→AL→CA. The parameter details are in
Note: The controller will automatically exit viewing mode after 5 seconds of inactivity.
2.4 Parameter Settings
STC-1000Pro supports parameter settings by buttons.
Button Operation
Press and hold
button for 3 seconds to enter the parameter setting mode, the buzzer will
beep and the LCD will display
Press
button to switch to the next parameter, then press
the setting value; or long press
Press and hold
for 3 seconds to save settings and exit; or the controller will save and exit
setting mode after 15 seconds of inactivity.
See the flow chart below for quick parameter setting procedures:
Press SET button
for 3s
Press SET button for
3s/ 15s of inactivity
parameter viewing
icon.
or
to increase or decrease quickly.
Temperature
Cooling
Set Value
Di erential
Temperature
Temperature
Unit
Calibration
mode.
or
Heating
Di erential
Low
Alarm Limit
4
2.4 Parameter Settings.
to increase or decrease
Protection Time
High
Alarm Limit

Publicidad

loading