P1 - LIMIT SETTING AND MOTORS STEERING SETTINGS
EN
Open limit, close limit, motor steering settings, the controller initially installed can operate
normally throught the following steps setup.
Note: On first use, manually put the door in half.
Setup steps:
Press and hold
Press and hold
Press
Note: After the motor is configured, verify that the limits are correct.
52
MATIKGATE AUTOMATION
Adjust the door to middle position.
(SET - located on the board) until appears on the display "P--1".
Press
one time, a value appears on the display.
Press and hold
until the door rises to the desired position.
If the door goes down, turn off the power
Press
Appears on display "P--2".
Press
one time, a value appears on the display.
until the door comes down to the desired position.
Press
Appears on display "P--3".
six times until leave the programming, appears on display "----".
Power on.
Replace motor wires, L1 with L2.
Start from beginning.
one time, to save the setting.