Descargar Imprimir esta página

Matikgate BOLT Manual De Usuario/Instalador página 68

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN
When the control unit is in standby, it can read the input status from the display.
No active input
Active stop contact
Photocell contact 2
Active photo contact
Guaranteed close input active
Active start input
Active pedestrian entrance
Attention:
During automatic close, the display shows the countdown from the seconds to closing.
POTENTIOMETERS
TR1 = SD SPEED - Speed regulation in deceleration.
TR2 = FORCE - Force regulation / Obstacle detection.
TR3 = SD Time - Regulation of the slowdown time.
PROGRAMMING WORKING TIME AND TRANSMITTERS
Lt
QUICK PROGRAMMING WORKING TIMES
To quickly program the working times, press and hold UP (3 seconds) until
If the door is not fully closed, it will close to the limit switch, then open at the open limit switch, and finally close once.
If you are not sure which direction the door is facing, place it in the fully closed position before starting programming, the
board will assume the limit switch as the close side and automatically manage the motor direction (see menu
advanced menu).
c1
QUICK PROGRAMMING OF TRANSMITTERS
Press shortly DOWN to record a transmitter,
Then press the button of the transmitter you want to program.
rM
Check the
parameter if the emitter does not work. It should be in
Ar
AUTOMATIC PROGRAMMING OF TRANSMITTERS
It is possible to record transmitters quickly without using the basic menu.
To insert a new transmitter with the gate closed, transmit 3 times with the new transmitter, pausing at least 1 second between each
transmission.
Then transmit 3 times with the transmitter already in memory and once with the new one. Once programming is complete, the
board's stop led flashes once.
This function must be enabled, see the advanced menu
MM
MASS ENTERING MODE (exclusive function for use in barriers)
In this mode, press the OPEN command 5 times (example), the control panel counts 5 passes through the detection sensor (DET
input, guaranteed closing function), then closes the door.
This mode must be enabled in the advanced menu (
68
MATIKGATE AUTOMATION
CONNECTIONS STATUS
c1
appears in the display.
1b
.
Ar
.
MM
). It can be enabled only when automatic closing is disabled.
Active opening input
Close input active
Close limit switch
Close limit switch
Self-closing seconds count (blink)
Count "mass mode" (fixed)
Lt
appears on the display.
Gd
in the

Publicidad