WORKING TIMES MENU: In this menu it's possible to modify the working times of the control unit.
t1
Working time.
tP
Pedestrian time.
tc
Courtesy light time (in ten seconds).
EH
Exits from advanced menu.
Once selected the working time to be changed, use the UP/DOWN buttons to change it from 0 to 99 secondes.
Press ENTER to confirm.
To exit without modification, select
Gd
ROTATION SENSE
Defines the rotation sense, whether it is to the right (
Pc
PHOTOCELLS INPUT
Defines whether the photocell input is NO or NC. Use UP/DOWN buttons to choose NO (
Press ENTER to confirm.
Pt
PHOTOSTOP / PROTECTION INPUT POLARITY
Defines whether Photostop/Protection input is NO or NC. The
while it works as a protection when the barrier mode is selected (see advanced menu
SP
STOP INPUT POLARITY
Defines whether the STOP input is NO or NC. Use the UP/DOWN buttons to choose NO (
Press ENTER to confirm.
LS
LIMIT SWITCHES POLARITY
LS
is NO or NC. Use UP/DOWN buttons to choose NO (
Defines whether
Press ENTER to confirm.
SS
SOFT START
Set whether soft start is enabled (
bL
BLINKER MODE
YS
Board flashes (
). Flashing made by flash light (
d2
LOAD DEFAULTS
Choose this menu and confirm with yes (
in this manual to check the value set with this command.
Ar
AUTOMATIC LEARNING OF RADIO CODES
Enable this function, the board is able to read radio codes without operating on it (check the paragraph of the automatic radio
code learning function). Use UP/DOWN buttons to choose yes (
rM
RADIO MODE:
Each button of a new transmitter enter separately.
1b
User can choose associated channel (
After inserting a button into the transmitter in memory, all other buttons work.
4b
Each button has a channel between (open, close, pedestrian and stop).
cn
COUNTER
Shows the counter in 3 groups of 2 numbers. Example: 123.456 is displayed as:
MM
MASS MODE
In this menu, you can activate mass input mode. This mode can only be enabled when the pause time is 0, that is, when automatic
closing is disabled. In this mode, by pressing the opening command 5 times (example), the control unit will count 5 passes through
the detection sensor, until the door is closed.
br
BARRIER LOGIC
YS
Select
from this menu if operating with a barrier. Select
ADVANCED MENU ADJUSTMENT
EH
or press the UP and DOWN buttons at the same time.
rh
) or to the left (
YS
nt
) or not (
). Soft start makes a linear power slope to avoid mechanical shock at start.
nt
).
YS
), set the control unit to factory defaults. Be careful, check the default settings table
c1
c2
Start/Open,
nt
LF
). Use UP/DOWN buttons to choose, ENTER to confirm.
no
Pt
input works as a photocell if the sliding door mode is selected,
br
).
no
no
nc
), NC (
) or exit (
YS
nt
EH
), not (
) or exit (
). Press
c3
Pedestrian/Close,
courtesy light).
12 - 34 - 56
to operate with sliding doors.
nc
EH
), NC (
) or exit (
).
nc
EH
), NC (
) or exit (
).
EH
).
ENTER
to confirm.
.
MATIKGATE AUTOMATION
EN
71