102.3 kN
692 bar
P
= 692 bar
m
565 bar
max.
min.
The capacitive menu selection button may not work if touched using objects or when wear-
BATTERY
BATTERY
ing gloves, therefore always operate it using a bare finger.
4.2) SELECTION SCREENS:
of the tool, can be changed by operating the touch button:
Enabling/disabling the LED Worklights
LED
BATTERY
ON
LED
BATTERY
OFF
Return to original factory settings / firmware version
13001
When the "RESET" screen is displayed, return the tool to its factory setting by operating the touch
button for at least 3 seconds; a beep will confirm the setting.
RESET
SW:S1J41413
4.3) WARNINGS:
LED
OFF
BATTERY
LED
ON
BATTERY
13001
RESET
SW:S1J41413
11
OK
B1350
13AB485
OK
To make a selected screen operational and appear at each start-up of the
tool, operate the touch button for at least 3 seconds; a continuous beep
3 SEC.
will confirm the setting.
control parameters that cannot be set as automatic upon start-up
3 SEC.
The RESET screen also shows the firmware version of the circuit board.
these appear during operation and notify the operator of the status of the tool:
LOW BATTERY: replace the battery.
NOTE: when the battery Vage falls below a minimum safety threshold, the tool
will not start; although it is still possible to end the work cycle in progress.
BATTERY TEMPERATURE HIGH: remove the battery and wait until it cools
down.
NO. OF CYCLES TO MAINTENANCE REACHED:
(13000 B1350-C and 30000 B1350L-C) the tool continues to work however, it
is recommended that it is sent to CEMBRE for a complete overhaul (see § 6).
NOTE: this message, together with a beep, will reappear when the tool has
been idle for 30 seconds.
BATTERY
13001
RESET
SW:S1J41413
(factory setting LED ON)
LED
ERROR
OFF
LED
ON
001
002
003
004
ERROR
001
002
003
004
When the screen is displayed,
touch the button for at least 3 sec-
onds to deactivate for reactivate
operation of the LED Worklights
during tool use; a continuous
beep will confirm the setting.
001
002
003
004