LEGIONELLA BACTERIA FUNCTION
Legionella are small rod shaped bacteria which are a natural constituent of all fresh waters. Legionaries'
disease is a pneumonia infection caused by inhaling of Legionella species. Long periods of water stagna-
tion should be avoided; it means the water heater should be used or flushed at least weekly.
The European standard CEN/TR 16355 gives recommendations for good practice concerning the preven-
tion of Legionella growth in drinking water installations but existing national regulations remain in force.
This electronic storage water heater is sold with a thermal disinfection cycle function enabled by default.
Every time the product is switched on and every 30 days, the thermal disinfection cycle run to heat the
water heater up to 65°C.
Warning: when this software has been carrying out the thermal disinfection treatment, water temperature
can cause burns. Feel water before bathing or showering.
TECHNICAL CHARACTERISTICS
For the technical specifications, refer to the nameplate (the nameplate is located next to the water in-
take/outlet pipes). Product can't work in "off peak" installation.
Product range
Weight
Installation
Model
Q
kWh
elec
kWh
Q
elec , week, smart
Q
kWh
elec , week,
Load profile
L
wa
η
wa
Capacity
The radio frequency band equipment operates is 2.4 GHz, and the maximum power of the transmitted signal is < 20 dBm
The power consumption data in the table and the other information given in the Product Fiche (Annex A to
this manual) are defined in relation to EU Directives 812/2013 and 814/2013.
Products which do not have the label and Product Fiche required for boiler/solar power configurations
pursuant to regulation 812/2013 may not be used in such installations.
The appliance has a smart function which adapts consumption to the user's use profile.
If used properly, the appliance has a daily consumption of "Qelec (Q
than that of an equivalent product without the smart function.
The data on the energy label apply to the product when installed vertically
The appliance is conforming with international electrical safety standard IEC 60335-1;
IEC 60335-2-21.
The CE marking applied to the appliance certifies that it conforms with the essential requirements of
the following European Directives:
- Low voltage directive (LVD): EN 60335-1, EN 60335-2-21, EN 60529, EN 62233, EN 50106.
- Electromagnetic compatibility (EMC): EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3.
- ROHS 2 directive: EN 50581.
- ErP Energy related Products: EN 50440.
This product is in conformity with REACH regulations.
14 / EN
TABLE 1 - PRODUCT INFORMATION
10
kg
6,6
Oversink
2,548
9,930
11,436
XXS
38,4%
l
10
Undersink
Oversink
Refer to the nameplate
3,131
2,263
11,272
10,199
14,999
11,878
15 dB
36,6%
37,8%
15
7,4
Undersink
3,130
11,486
15,829
XXS
37,6%
15
/Q
) which is less
elec, week, smart
elec, week
30
12,8
Oversink
2,842
12,106
15,979
S
39,2%
30