Technical Specifications; Electrical Connection - Fagor FI-30 Instrucciones Generales Para Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para FI-30:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

1.1.- Installation diagrams
See Fig.1.
1.2.- Positioning
Level and adjust the height of the appliance. (Fig. 2)
1.3.- Water connection
To be done as shown in figures 3 and 4.
Dynamic pressure necessary during rinse: 2 - 4 Kg/cm
2
Kg/cm
, install an electrical pressure pump. (Fig.4).
When the water hardness level is above 10º dF, a water softener should be installed.
1.4.- Drainage
a) Fix the drainage hose as indicated in Fig.5.
b) Fit a siphon pipe to prevent bad smells.

1.5.- Technical specifications

Water
MODEL
inlet
pressure
FI - 30
FI - 48
FI - 48B

1.6.- Electrical connection

− For access to the connection strip (R), (Fig. 1 and Fig. 6), remove the cover (T) and the
rear panel (P). Fix the sheathed cable to (E) leaving enough cable to remove the electrical
panel from the front.
− Connect the strip as shown in figure 6.
− Fit a general switch (I) independent of the appliance with a distance between contacts
equal to or more than 3 mm.
− The machine must be earthed.
Voltage
220-240-1N~
380-415V-3N~
1.- INSTALLATION
Supply
Power (Kw)
voltage
H. element
Drum
Tub
2,8
2,8
MODEL
S. cable
FI - 30
2
FI - 48
2x2.5mm
FI - 48B
FI - 30
2
FI - 48
4x2.5 mm
FI - 48 B
2
. With mains pressures of less than 2
Square
Max
basket
absorb.
(mm)
3,45
500x500
3,52
Fuses
+ T
20 A
+ T
20 A
9
Cycle
Tub
duration
capacity
(l)
4' Reg.
25
120''
180''
Mains connection
Rinse
Net
water
weigh
cons (l)
(Kg)
54
2,7
59
60