TROUBLESHOOTING
PUMP DOES NOT REACH WORKING PRES-
SURE
Nozzle worn: Replace nozzle.
Water filter fouled: Clean filter.
Water supply pressure low: Turn on water sup-
ply tap fully.
Air being sucked into system: Check tightness
of hose fittings.
Air in pump: Switch off the appliance and keep
depressing and releasing the gun trigger until
the water comes out in a steady flow. Switch
the appliance back on again.
Adjustable nozzle not positioned correctly:
Turn the adjustable nozzle (+).
PRESSURE DROPS DURING USE
Water intake from external tank: Connect ap-
pliance to the mains water supply.
Intake water too hot: Reduce temperature.
Nozzle clogged: Clean nozzle.
MOTOR "SOUNDS" BUT FAILS TO START
Insufficient power supply: Check that the volt-
age of the mains power supply line is the same
as that on the plate.
Voltage loss due to use of extension cable:
Check characteristics of extension cable.
Appliance not used for a long period of time:
Contact your nearest Authorized Service Cen-
ter.
Problems with TSS device: Contact your near-
est Authorized Service Center.
MOTOR FAILS TO START
No electrical power: Check that the plug is
firmly in the socket and that the mains voltage
supply is present.
Problems with TSS device: Contact your near-
est Authorized Service Center.
Appliance not used for a long period of time:
Using the tool un-jam the motor from the hole
at the rear of the appliance (in models with
this feature).
WATER LEAKAGE
Seals worn: Have the seals replaced at your
nearest Authorized Service Center
APPLIANCE NOISY
Water too hot: Reduce temperature (see tech-
nical data).
E N G L I S H •
OIL LEAKAGE
Seals worn: Contact your nearest Authorized
Service Center.
MOTOR STARTS EVEN WITH GUN TRIGGER
IS RELEASED
Nozzle clogged: Clean nozzle.
High pressure system or pump hydraulic circuit
not watertight: Contact your nearest Autho-
rized Service Center.
TECHNICAL DATA
VOLTAGE-FREQUENCY
MAX. PRESSURE
MAXIMUM PRESSURE OF
WATER INLET
MINIMUM FEEDING
FLOW
POWER
WEIGHT
U se r' s m a nu a l
120 V ~ 60 Hz
15,17 MPa (2 200 PSI)
147 kPa
8 L/min
6 L/min
2 000 W
14 kg (30,8 lb)