Preparation For Use; Break-In Procedure - DeWalt D55672 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LIFTING
Always use two people when lifting and lift from the recommended
lift points (R).
WARNING: Risk injury from lifting. Unit weighs more than 160 lbs.
(72.6 kg) Do not move or lift without assistance.
CAUTION: Risk of property damage. Place engine fuel valve lever
(O) in the OFF position before moving or transporting unit.
MOVING
1. Grasp handle (S) of compressor, and lift compressor high
enough so unit can be rolled on the front tire(s).
WARNING: Risk of unsafe operation. Ensure proper footing and
use caution when rolling compressor so that unit does not tip or
cause loss of balance.
CAUTION: Risk of property damage. Place engine fuel valve lever
(O) in the OFF position before moving or transporting unit.
2. When location is reached slowly lower rear of compressor to
ground. Always store compressor in a horizontal position. NOTE:
DO NOT store in a standing position.
NOTE: Should the unit tip over, hard starting and smoking will occur
due to oil spillage.

PREPARATION FOR USE

Pre-Start Checklist (Fig. 1)
1. Ensure engine ON/OFF switch (C) is in the OFF position.
2. Ensure air tank is drained, see Draining Air Tank under
Maintenance.
3. Ensure the drain valve (J) is closed.
4. Ensure safety valve (I) is functioning properly, see Checking
Safety Valve under Maintenance.
5. Check pump oil level, see Compressor Pump Oil under
Maintenance.
CAUTION: Do not operate without oil or with inadequate oil. D
is not responsible for compressor failure caused by inadequate oil.
6. Check engine's oil and fuel level, see engine's instruction manual
for correct procedures.
7. Visually inspect drive belt. Replace belt if frayed, cracked, or worn.
NOTE: Outer belt cover must be removed to inspect drive belt.
8. Ensure all guards, covers, and labels are in place, legible (for
labels) and securely mounted. Do not use compressor until all
items have been verified.
Initial Set-up (Fig. 1)
WARNING: Do not operate this unit until you read and understand
this instruction manual and the engine instruction manual for safety,
operation and maintenance instructions.

BREAK-IN PROCEDURE

WARNING: Risk of property damage. Serious damage may result if
the following break-in instructions are not closely followed.
This procedure is required:
• Before the air compressor is used for the first time.
• When the unloader valve has been replaced.
• When the compressor pump has been replaced.
The procedure:
1. Follow Pre-Start Checklist under Preparation for Use.
2. Rotate the unloader's manual lock to the open position to
prevent air tank pressure buildup.
3. Open the pressure regulator. Pull regulator knob (F) out and rotate
clockwise until it stops.
WARNING: Do not operate this unit until you read and understand
the engine instruction's manual for safety, operation and maintenance
instructions.
13
WALT
E

Publicidad

Tabla de contenido
loading

Tabla de contenido