Assembly Sequence - Konigshutte Virgo Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Stove rotating
The wall distances for rotating installation are present-
ed below.
100 cm
45°
Fig.5 Stove rotating, installed straight in corner
40 cm
45°
Fig.6 Stove rotating, installed diagonally in corner

Assembly sequence

● The Ø 150 stovepipe connection can be installed at
the top or rear. The stove is supplied ready for con-
nection from above. If you wish to connect it at the
rear, the following steps must be carried out to make
the necessary modifications:
- Break out the cover in the back panel.
- Replace the connector sleeve and the sealing
cover.
● Install the pipe lining (provided on site) in the chim-
ney. The connection height can be individually spec-
ified for a top stovepipe connection, however should
not exceed 1.5 m from the connector sleeve. For the
100 cm
rear stovepipe connection heights please refer the
"Technical Data" chapter. No combustible material is
permitted within a radius of 20 cm around the stove
pipe.
45°
● Connect the stovepipe at both connection points
with stove putty so that the stove pipe is permanent-
ly sealed.
● Push the stove onto its planned position and orient it
so that the stovepipe fits into the pipe lining.
The stovepipe connections must be tight. The
stovepipe must not protrude into the chimney.
Bear in mind that on partition walls in accordance
with test specification EN 13240 the temperature
of 85°C can be reached, and with light wallpaper
or similar combustible construction materials this
can result in colour changes.
45°
13

Publicidad

Tabla de contenido
loading

Tabla de contenido