Installation and connection
The pump can be installed submerged (in water) or dry (outside the water).
The use of the pump is only permitted with observance of the specified water quality.
(→ Permissible water quality)
• Pool water or salt water can impair the appearance of the unit. Such impairments are excluded
from the guarantee.
WARNING
The power supply carries dangerous electrical voltage and must not be placed directly near wa-
ter. Otherwise, there is a risk of serious injury or death from electric shock.
The transformer is subject to dangerous voltage and must not be installed directly adjacent to
the water. Otherwise there is a risk of severe injuries or death by electrocution.
Install the power supply in a flood-protected position at least 2 m from the water.
CAUTION
Rotating components in the intake and pressure socket area. Risk of injury when reaching into
the sockets.
In particular, observe the following: A unit that has stopped due to overload can start up unex-
pectedly!
Do not reach into the opening of the intake socket or pressure socket while the power plug is
plugged in.
If the sockets are freely accessible during operation, e.g. if no hoses are connected, use a hand
guard to secure the sockets. The hand guard is available as an accessory.
NOTE
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to in-
creased wear and will require earlier replacement.
Thoroughly clean the pond or pool before installing the pump.
Install the pump at a raised level above the bottom of the pond. This reduces intake of muddy
water.
Avoid direct sunlight on unit components that are not submerged, as they may overheat. If
necessary, use a protective cover.
EN
27