Operation
Low Voltage Protection and Recovery Setting
When the LCD displays as above, press the SET key for 1s, the
controller's low voltage protection.
1. Lithium Battery
Low voltage protection setting range: 12/24V: 9.0-30.0V (default: 10.6V).
2. Liquid, Gel and AGM Battery
Low voltage protection setting range: 10.8 ~ 11.8V/21.6 ~ 23.6 (default: 11.2/22.4)..
The controller automatically calculates the low voltage recovery setting according to the low voltage
protection setting. It is approximately 1.11 times the low voltage protection setting. The default low
voltage recovery setting is 0.8/1.6V higher than the low voltage protection setting. To reduce the
recovery voltage, the protection voltage setting needs to be reduced first.
Clear Bluetooth Device Password
When the LCD displays as above, press the SET key for 1s, the
Bluetooth device password set by the mobile app
icon flashes, now you can set the
icon flashes, you can press OK to clear the
.
- 20 -
CCD-0007727 Rev: 06-01-23