Descargar Imprimir esta página

Furrion FSCC40PW2 Manual De Instrucciones página 4

Controlador de carga solar con mppt (detector de punto de conversión óptima) de 40/60 amp para montaje en pared con aplicación bluetooth

Publicidad

Idiomas disponibles

Idiomas disponibles

Important Safety Instructions
IMPORTANT: SAVE THESE INSTRUCTIONS– This
manual contains important instructions for
Models FSCC40PW2 and FSCC60PW2 that shall
be followed during installation and operation
of the charge controller. The following symbols
are used throughout the manual to indicate
potentially dangerous conditions or important
safety information.
WARNING
Indicates a potentially dangerous condition. Use
extreme caution when performing this task.
CAUTION
Indicates a critical procedure for safe and
proper operation of the controller.
NOTE: Indicates a procedure or function that is
important to the safe and proper operation of
the controller.
General Safety Precautions
Read all instructions and warnings in the
manual before installation.
● There are no user serviceable components
inside of the controller. DO NOT disassemble
or attempt to repair the controller.
● Mount the controller indoors. Prevent
exposure to the elements and do not allow
water to enter the controller.
● Install the controller in a well ventilated area
as the unit may become hot during normal
operation.
● Install appropriate external fuses or circuit
breakers.
● Disconnect all connections with the solar
panels and the fuses or circuit breakers prior
to controller installation or adjustment.
● Ensure connections remain tight to avoid
excessive heat.
CCD-0007727 Rev: 06-01-23
Charge Controller Safety
● NEVER connect the solar panel array to the
controller without connecting a battery to
the controller first.
● Ensure input PV voltage does not exceed 95
VDC (25°C) for FSCC40PW2, FSCC60PW2 to
prevent permanent damage. Use the Open
Circuit Voltage (Voc) parameter of the solar
panels to make sure the voltage does not
exceed this value when connecting panels
together.
Battery Safety
● For use with sealed lead acid, GEL, AGM
(absorbent glass mat), and LiFePO4
batteries.
● Explosive battery gases may be released
while charging certain batteries. Be certain
there is enough ventilation to release the
gases.
● Be careful when working with lead acid
batteries. Wear eye protection and have
fresh water available in case there is contact
with the battery acid.
● Carefully read battery manuals before
operation.
● Do NOT let the positive (+) and negative (-)
terminals of the battery touch each other.
● Properly dispose of battery when replaced.
- 3 -