PROBLEM
Motor will not
run.
CAUSE
Fuse blown, circuit breaker
tripped.
Extension cord is wrong
length or gauge.
Loose electrical
connections.
Faulty motor.
CORRECTION
Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a fuse
or circuit breaker with higher
rating than that specified for
your particular branch circuit.
Check for proper fuse. You
should use a time delay fuse.
Check for low voltage
problem.
Check the extension cord.
Disconnect
the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
Check the extension cord.
Check wiring connection
inside terminal box.
Have checked by a Trained
Service Technician.
21- ENG
N000317