Specifications
Pressure ranges
Over pressure safety
Burst pressure
Materials
Wetted parts
Case
Electrical connection
Response time (10 ... 90 %)
Non-linearity
Accuracy
1-year stability
Permissible temperature of
Medium
Ambience
Storage
Compensated temp range
Temperature influence
Mean TC of zero
Mean TC of range
20
Betriebsanleitung/Operating instructions/Mode d'emploi/Instrucciones de servicio
Model P3308
bar
0...6 bar to 0...60 bar, -1..7 bar, -1..9 bar, 0..30 bar, others on request
bar
40 bar 2 x ; >40 bar 1,6 x
bar
6 x
other measuring ranges on request
{Vacuum, gauge pressure, compound range are available}
Stainless steel
Stainless steel
Highly resistive, fibreglass-enforced plastic (PBT GF 30)
Signal output
4 ... 20 mA, 2-Leiter
0 ... 10 V, 3-Leiter
0.5 ... 4.5 V, ratiometric
ms
5
%
±1% BFSL acc. to IEC 61298-2
% of span
2.0
* )
Including non-linearity, hysteresis, zero point and full scale error
(corresponds to error of measurement per IEC 61298-2).
% of span
0.3 (at reference conditions)
-40 ... +80 °C
-25 ... +80 °C
-25 ... +80 °C
-25 ... +80 °C
% of span
typ. 0.5 / 10 K
% of span
0.3 / 10 K
Power supply U
B
7 ... 30 VDC
14 ... 30 VDC
5 ± 0.5 VDC
-40 ... +176 °F
-13 ... +176 °F
-13 ... +176 °F
-13 ... +176 °F
GB
Max. load R
A
R
(UB – 7 V)/0.02 A
A
R
> 10 kOhm
A
R
> 4.5 kOhm
A