- FUNCTIONALITIES
FIRST FILL-UP:
- If the boiler and tank are completely emp-
ty, all system functions are disabled.
- Assure the presence of water in the tank,
and manually fi ll if empty.
- With the tank full and the boiler empty,
after feeding the generator through the
switches (see the "PREPARATION" para-
graph), the system controls the water fi lling
pump until the correct level is reached in
the boiler. In this phase the heater is deac-
tivated, while the signal lamp (2 fi g.4) is on
without blinking and without an acoustic
signal; this indicates the fi lling procedure in
process.
- Once fi lling is completed, the pump is tur-
ned off, and heating is simultaneously ena-
bled through the boiler heater; the signal
lamp is turned off (2 fi g.4).
LEVEL ADJUSTMENT:
BOILER:
- Refi lling is carried out each time the level
probe senses a low water level in the boiler.
During normal level recovery, the heater
remains enabled for heating and the signal
lamp (2 fi g. 4) is on without blinking and
(2 - fig.10)
without acoustic signal.
- If during filling the level probe located
- If during fi lling the level probe located in
in the tank H
O (Fig.11) should remain
the tank should remain exposed, the sy-
2
exposed, the system immediately stops
stem immediately stops refi lling operations
refilling operations and the signal lamp
and the signal lamp (2 fi g.4) starts blinking
(2 fi g.4) starts blinking together with an
together with an intermittent acoustic si-
intermittent acoustic signal.
gnal.
- Each time the tank level probe senses a low
water level, the system immediately stops
refi lling operations and the signal lamp (2
fi g.4) starts blinking together with an inter-
Fig.10)
mittent acoustic signal.
- Refi ll the tank to reset the alarm.
(2-fig.10)
(2-fig.10).
(2-fig.10)
English
ALARM SIGNALS:
-
fi lling phase the boiler level probe
remains exposed for more than 3
disables heating and refi lling functions, and
the signal lamp starts blinking along with an
acoustic signal. At this point the generator
must be reset by turning the general switch
off and then back on (3 fi g. 4).
WARNING:
THERMOREGULATOR ADJUSTMENT:
Fill the boiler tanks with water only.
With our temperature / pressure electronic
control system, if necessary it's possible to set
- Never use detergents or chemicals.
39
If during the normal re-
consecutively, the system
(1-fig.8).