Descargar Imprimir esta página

Kenmore ELITE trio 596.7759 801 Serie Manual De Uso Y Cuidado página 21

Refrigerador con congelador en la parte inferior

Publicidad

Idiomas disponibles

Idiomas disponibles

PRODUCT DATA SHEETS
Interior Water Filtration System
Model 469006-750
Capacity
750 Gallons
(2839 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of Lead,
Mercury, Atrazine,
Benzene,
p-Dichlorobenzene,
Carbofuran,
Toxaphene,
Cysts, Turbidity, Asbestos
and Lindane.
This system
has been
tested
according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed
below.
The
concentration
of the indicated
substances
in water
entering
the system
was reduced
to a concentration
less than or equal to the
permissible
limit for water
leaving
the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
1.88 mg/L
2.0 mg/L _+10%
0.06 mg/L
**
0.05 mg/L
96.84
>97.26
Particulate Class I*
85% reduction
5,700,000 #/mL
At least 10,000
69,000 #/mL
30,583 #/mL
98.94
99.52
particles/mL
Contaminant
NSF Reduction
Average
Influent
Challenge
Maximum
Average
Minimum%
Average%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
0.153 mg/U
0.15 mg/L + 10%
< 0.001 mg/L
< 0.001 mg/L
>99.29%
>99.35%
Lead: @ pH 8.5
0.010 mg/L
0.150 mg/U
0.15 mg/L _+10%
< 0.001 mg/L
< 0.001 mg/L
>99.29%
>99.33%
Mercury: @ pH 6.5
0.002 mg/L
0.006 mg/L
0.006 mg/L + 10%
0.0005 mg/L
0.0003 mg/L
90.91
95.70
Mercury: @ pH 8.5
0.002 mg/L
0.006 mg/L
0.006 mg/L _+10%
0.0015 mg/L
0.0008 mg/L
75.93
86.22
Benzene
0.005 mg/L
0.014 mg/L
0.015 mg/L _+10%
0.0011 mg/L
0.0006 mg/L
92.14%
95.71%
p-Dichlorobenzene
0.075 mg/L
0.208 mg/L
0.225 mg/L _+10%
< 0.0005 mg/L
< 0.0005 mg/L 99.74%
99.76%
Carbofuran
0.04 mg/L
0.081 mg/L
0.08 mg/L _+10%
< 0.001 mg/L
< 0.001 mg/L
98.46%
98.74%
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 _+10%
< 0.001 mg/L
< 0.001 mg/L
91.67%
92.97%
Atrazine
0.003 mg/L
0.009 mg/L
0.009 mg/L _+10%
< 0.002 mg/L
< 0.002 mg/L
75.31%
76.99%
Asbestos
99%
155 MF/L
107to 108fibers/U _
<1 MF/L
<1 MF/L
>99.99%
>99.99%
Live Cysts _
>99.95%
166,500 #/L
50,000/L min.
<1 #/U
<1 #/U
>99.99
>99.99
Turbidity
0.5 NTU
10.7 NTU
11 _+1 NTU
0.49 NTU
0.31 NTU
95.2
97.09
Lindane
0.0002 mg/L
0.002 mg/L
0.002 _+10%
< 0.0001 mg/L
0.000 mg/L
96.50%
98.72%
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure
71.6°F (20°C to 22°C).
It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as
advertised.
The disposable water filter should be replaced at least every
6 months.
The filter monitor system measures the amount of water that
passes through the filter and alerts you to replace the filter.
When 90% of the filter's rated life is used, the yellow (Order)
light comes on. When 100% of the filter's rated life is used,
the red (Replace) light comes on, and it is recommended
that
you replace the filter. For models without filter status lights,
replace the filter every 6 months. Use replacement filter
model 469006-750.2007
suggested retail price of
$49.99 U.S.A./S65.95 Canada. Prices are subject to change
without notice.
= 60 psig (413.7 kPa). Temp. = 68°F to
Refer to the "Water Filtration System" section for the Manufacturer's
name and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
35 - 120 psi (241 - 827 kPa)
Water Temperature
33 ° - 100°F (1o _ 38oC)
Service Flow Rate
0.78 gpm (2.9 L/min.) @ 60 psi.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tThese contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark of NSF International.
21