Descargar Imprimir esta página

Carrier 40VD048-096A-7S-QEE 40VD048A-7S-QEE Manual De Instalación Y Operación página 10

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 112
Fault Check-up
Please check the following when consigning repair services:
Symptoms
Water flow sound
Cracking sound
Terrible smell in
outlet air
Flashing operating
indicator
Awaiting indication
Sound in shutdown
indoor unit or white
steam or cold air
Clicking sound
when switching the
air conditioner on
Starts or
stops working
automatically
Failure to work
Bad cooling &
heating effects
Under the following circumstances, immediately stop the operation, disconnect the manual supply
switch, and contact the post-service personnel.
When buttons are inflexibly activated;
When the fuse and breaker have been burnt over and over;
When there are foreign objects or water in the refrigerator;
When it cannot be operated even after removing the operation of protective unit;
When other abnormal conditions occur.
The sound of water flowing can be heard before, during or
immediately after operation. When it starts working for 2-3 minutes,
the sound may become louder, which is the sound of the refrigerant
flowing or the condensed water draining.
During operations, the air conditioner may make a cracking sound,
which is caused due to temperature changes or the slight dilation of
the heat exchanger.
The terrible smell caused from walls, carpet, furniture, clothing,
cigarette and cosmetics, attaches on the conditioner.
When switching it on again after power failure, turn on the manual
power switch and the operating indicator flashes.
The awaiting indication it is displayed when the machine fails to
refrigerate while other indoor units are heating. When the operator pre-
sets it to refrigerating or heating mode, but the operation is contrary to
the setting, the awaiting indication is displayed.
To prevent oil and refrigerant from blocking the shutdown of indoor
units, refrigerant flows in quickly and one can hear the sounds.
Otherwise, when other indoor units perform heating, white steam
may appear; during refrigeration, cold air may appear.
When the conditioner is powered on, the resetting of the expansion
valve emits a sound.
Check if the status is Timer-ON or Timer-OFF.
Check if there is a power failure.
Check if the manual power switch is turned off.
Check if the supply fuse and breaker are disconnected.
Check if the protective unit is working.
Check if refrigerating and heating functions are selected
simultaneously with the awaiting indication on line control.
Check if the air inlet outlet ports of outdoor units are blocked.
Check if the doors and windows are open.
Check if the filtering screen of the air cleaner is blocked with sludge
or dust.
Check if the setting of wind quantity is at low wind.
Check if the setting of operation is at the Fan Operation state.
Check if the temperature setting is correct.
5
Reasons

Publicidad

loading

Este manual también es adecuado para:

40vd072a-7s-qee40vd096a-7s-qee