INSTALLATION INSTRUCTIONS
ELECTRICAL CONNECTION
The dryer is set to 208-240 V and 60 Hz.
The dryer requires a special plug. This plug must
be connected to a grounded outlet protected by a
16 Amp fuse or breaker as indicated on the ratings
plate. The fuse/breaker rating of the power line to
which the outlet is connected must also be 16 Amps.
Consult a qualified electrician if you do not have the
correct outlet, fuse, or breaker.
Our company cannot be held responsible for
damages resulting from usage with grounding.
PLUG AND POWER CORD SELECTION
Select receptacle type.
4-WIRE RECEPTACLE
Requires UL listed NEMA 14-30P 240V / 30A
4-wire supply cord with ring terminals or spade
terminals with upturned ends. Supply cord must be
type SRDT and at least 5 feet (152.4 cm) in length.
3-WIRE RECEPTACLE
Requires UL listed NEMA 10-30P 240V / 30A
3-wire supply cord with ring terminals or spade
terminals with upturned ends. Supply cord must be
type SRDT and at least 5 feet (152.4 cm) in length.
4-WIRE POWER SUPPLY CORD
WARNING
• Before the connection, disconnect the power.
• Use UL listed 240V / 30A power supply cord.
The dryer is equipped with strain relief. Use this
strain relief for the connection.
1. Remove the screw and terminal box cover.
2. Remove the clamp of the strain relief which is
attached on our machine. Pass the clamp through
the supply cord and put the supply cord through
the main body of the strain relieve. Ensure the wire
insulation of the cord is inside the strain relief.
3. Remove the terminal block screws which are
indicated by A and the grounding screw which is
indicated by B. Neutral ground conductor (central
terminal) is provided in the dryer as a closed loop.
7