Product Description
This product is a non-regulating, relay valve designed to provide control of air flow to the starter motor in an air starter-based, internal
combustion engine starting system.
ST400 - D339-12 12 Volt DC
ST400 - D339-24 24 Volt DC
General Product Safety Information
Read and understand this manual before operating this product.
It is your responsibility to make this safety information available to others that will operate this product.
Failure to observe the following warnings could result in injury.
Always install, operate, inspect and maintain this product in accordance with all applicable standards and regulations (local, state,
country, federal, etc.).
Product Safety Information
This Starter Relay Valve is designed by Ingersoll Rand specifically for use on Air Starter installations. Any other use may result in injury or
equipment damage.
Only use this Starter Relay Valve at or below 225 psig (15.5 bar/1550 kPa) maximum pressure, unless otherwise labeled. Higher pressure
may result in hazardous situations including rupture of the Starter Relay Valve and associated hardware.
To use this Starter Relay Valve at a pressure of 225 psig (15.5 bar/1550 kPa), all associated pipe, hose and fittings must be rated at 225 psig
or more.
Do not use this Starter Relay Valve with any corrosive gas or with any liquid.
This Starter Relay Valve was designed for use with compressed air only. Do not use with natural gas or other flammable gases.
Always shut-off the air supply to the Starter Relay Valve, and bleed off any residual pressure, before performing any maintence on the
Starter Relay Valve.
Never remove the Retaining Ring from the Starter Relay Valve unless all pressure has been bled off. Internal parts will be forcefully ejected
if Retaining Ring is removed while pressurized.
Always wear eye protection when performing any maintenance on this Starter Relay Valve.
Do not remove any labels. Replace any damaged label.
Never use a damaged or malfunctioning Starter Relay Valve.
Do not modify the Starter Relay Valve.
Do not use this Starter Relay Valve for purposes other than those recommended.
Be sure all hoses & fittings are the correct size & are tightly secured.
Do not use damaged, frayed or deteriorated air hoses & fittings.
Safety Symbol Identification
Read Manuals Before Operating Product
Safety Information - Explanation of Safety Signal Words
DANGER
WARNING
CAUTION
NOTICE
EN-1
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or
property damage.
Indicates information or a company policy that relates directly or indirectly to the safety of personnel or
protection of property.
WARNING
WARNING
NATURAL GAS OR OTHER
FLAMMABLE GASES
DO NOT USE WITH
47518831001_ed1