Product Parts Information
The use of other than genuine Ingersoll Rand replacement parts may result in safety hazards, decreased Starter Relay Valve
performance, and increased maintenance, and may invalidate all warranties.
Repairs should be made only by authorized trained personnel. Consult your nearest Ingersoll Rand Authorized Service Center.
Placing the Starter Relay Valve in Service
AIR SUPPLY
(Dwg. 47516788)
This Starter Relay Valve is specially designed and manufactured by Ingersoll Rand for use on Starter installations. Install it in
accordance with the following instructions.
Pre-Installation
1.
Clean the air line, O-ring groove and sealing surfaces to be sure they are free of foreign material.
2.
Ensure that enough space is left for removal and service of this valve.
3.
Ensure that the air line is suitably aligned and supported to avoid strained joints.
4.
Do not over tighten the air line connections.
5.
Apply thread sealant to any NPT air line connection.
Installation of the Starter Relay Valve
1.
Place the O-ring supplied with the assembled ST400-16 Flange Assembly into the groove on the Starter Hose.
2.
Mount the Starter Relay Valve to the tank using ST400-16 Flange Assembly. The air flow arrow must point toward the starter.
3.
Check the O-ring to see that it properly seated in the groove to prevent cutting.
4.
Push the two clamp halves inward as far as they will go.
5.
Tighten the four flange bolts in an alternating pattern to 35-45 ft-lbs (47-61Nm) torque.
47518831001_ed1
CAUTION
NOTICE
TYPICAL INSTALLATION
TO AIR STARTER MOTOR
EN
EN-2