Trouble Shooting Guide
How to clean the transducer:
Clean with clean water or citric acid if there is scale in it.
1
Brush off the scale from the surface.
2
Rinse the transducer with clean water.
3
How to clean ceramic filter
Clean and activate the ceramic ball filter after using 1000L water regularly. Depend on water
1
quality. If ceramic ball is dirty, it needs to be cleaned more frequent.
It can be dipped in vinegar about 5 minutes. Then rinse it cleanly with clean water.
2
Then put filter under the sun for 4~6 hours.
3
Trouble Shooting Guide
If any trouble is found in normal operation, please kindly refer to the following points:
Trouble
Power lamp off,
does not work
Power lamp on, no
mist outlet with wind
Abnormal smell mist
Power lamp on,
unit doesn't work
Mist fog is too low
Abnormal noise
Mist fog coming out
from around nozzle
DISPOSAL
Do not dispose this product as unsorted municipal waste, collection of such waste separately for
special treatment is necessary.
Possible reasons
No power supply
1. No water in water tank
2. Security switch is too loose
1. New unit
2. Dirty water or water
sitting too long
Too much water in the water tank
1. Too much scale in the water tank
2. Water is too dirty or water kept
too long in the tank
1. Resonant in water tank when
water is too low
2. Unit is on a unstable surface
There are apertures between the
nozzle and water tank
Solution
Connect power supply,
switch on
1. Fill water into water tank
2. Tighten the switch
1. Take out water tank, open cover,
let it stay 12 hours in cool position
2. Clean water tank, fill with clear
water
Pull out same water from the water
tank, close the cover of water tank
tightly
1. Clean transducer
2. Clean water tank, change to
fresh clear water
1. Fill water into water tank
2. Move the unit to a stable flat
surface
Dip the nozzle in water for a while
and then fix it to the socket on
water tank