With the valve in the gas tank open.
a) Automatic ignition:
b) Manual ignition:
NOTE: in the event of difficult or irregular ignition, make sure that
nothing is blocking the fan and that it rotates freely.
3.3.2
Switching off
EN
Set the power switch (E) to the "I" position and the
electric motor will start, i.e. the fan will start to rotate
and the display on the right will show the ambient
temperature.
Press the gas valve (K) and set the power switch (E) to
the "II" position. The display on the left will show the
current temperature set on the device and the device
will automatically start the ignition if this temperature
is higher than the ambient temperature. If the ambient
temperature is higher than the set temperature, the
device will not start, unless the temperature control
knob (H) is set to a higher temperature.
Adjust the gas flow from the tank according to your
needs - by turning the regulator knob counterclockwise
to increase it, and the other way to reduce it.
If ignition occurs, but the heater is blocked after a few
seconds, the reset indicator (G) will illuminate. Wait a
minute and then press the reset button (F) and repeat
the above startup procedure from the beginning.
Set the power switch (E) to the "I" position and the
electric motor will start - the fan will start to rotate.
Press and hold the gas valve (K) and press the ignition
button (L) until the fire ignites. After the fire appears,
keep pressing the gas valve button for about 10
seconds.
In the event that after lowering the gas valve button (K)
the unit stops working, wait 1 minute and repeat the
above start-up procedure. However, after ignition, hold
down the gas valve button (K) a little longer.
Adjust the gas flow from the tank according to your
needs - by turning the regulator knob counterclockwise
to increase it, and the other way to reduce it.