BASIC ELECTRONIC LOCK — MANUAL PROGRAMMING GUIDE
Follow the instructions below to operate the electronic lock.
PIN CREDENTIAL:
1.
Enter a valid PIN (between 4 - 14 digits).
2.
Press "ENTER."
CARD CREDENTIAL:
If the electronic lock is equipped with a card reader (HID Proximity or HID iCLASS, iClass SE or iClass Seos):
1.
Present a valid card within range of the proximity card reader.
DUAL CREDENTIAL:
If the User or Supervisor requires a dual credential:
1.
Enter a valid PIN and press "ENTER" (for touchpad credentials) or present a valid card (for HID Proximity or HID iCLASS, iClass
SE or iClass Seos credentials).
2.
Enter the second credential (4-14 digit PIN) and press "ENTER."
NOTE:
1.
The second credential must always be a 4 - 14 digit pin.
2.
Lockview software and control substance drawer setup for dual credential programming.
Section 3: Adding & Deleting Users & Supervisors
ADD USER:
1.
Input a valid Supervisor PIN and press "ENTER" or present valid Supervisor card
2.
Press and hold "ENTER" until beeping stops
3.
Input the new User PIN and press "ENTER" or present new User card
ADD SUPERVISOR:
1.
Input a valid Supervisor PIN and press "ENTER" or present valid Supervisor card
2.
Press and hold "ENTER" until beeping stops
3.
Press and hold "ENTER" again until beeping stops
4.
Input new Supervisor PIN and press "ENTER" or present NEW Supervisor card
DELETE USER OR SUPERVISOR:
1.
Input a valid Supervisor PIN and press "ENTER" or present valid Supervisor card
2.
Press and hold "CLEAR" until beeping stops
3.
Input the PIN to be deleted and press "ENTER" or present existing card to be deleted
Section 4: Servo Calibration
1.
Enter Supervisor Code (default supervisor code is 1350) to unlock cart
2.
Press and Hold "1" and "5" simultaneously for one second, then release
3.
Automatic calibration procedure will begin (lock will open and close several times)
4.
When finished, LED lights will stop blinking and audible tone (3 beeps) will denote calibration was successful
5.
If calibration fails, denoted by audible tone (7 beeps), retry calibration or contact Metro Customer Service for support.
Section 5: Adjusting Auto Relock Timer Settings
NOTE: Factory default Auto Relock time is 5 minutes (300 seconds), Auto Relock Warning beeper is disabled by default
1.
To set the Auto Relock timer:
a.
Access the cart with a supervisor credential (default supervisor code is 1350)
b.
Type in the number of seconds you want the timer set for [valid range is 1 second to 18 hours (64,800 seconds)]
c.
Press and hold the Enter button
2
www.metro.com
L01-638
REV C 09/23