Descargar Imprimir esta página

Songmics LSD010 Manual Del Usuario página 11

Ocultar thumbs Ver también para LSD010:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
EN
For the first use, press and hold the "↓" button until it moves to the
lowest position and beeps. After, it can be raised and lowered
normally.
Indicator Light
Indicates normal and abnormal operating conditions of the desk.
Normal Height Adjustment
Press and hold the "↑" or "↓" button to set the desired height.
System Initialization
1. Forced System Initialization: Press and hold the "↓" button until
the desk moves to the lowest position. Release the "↓" button, then
press and hold the "↓" button again for 5 seconds until it beeps
and rebounds to complete the initialization.
2. Note: During system initialization, if the initialization is interrupted,
the "↑" button will not work and only the "↓" button will work.
When it beeps after the initialization, it means that the system
initialization is completed and the device will work normally.
Safety Function
If the desk encounters any resistance while moving, it will rebound
slightly, and the red light flashes.
Error Reports and Solution:
1. When the green light is on, it means that the system is working
normally. When both the green and red lights are on at the same
time, it means that the system is in test mode.
2. Refer to the following table for information about the flashing of
the red light:
Operation Guide
Up
Indicator Light
Signal
Flash once
Flash twice
Flash 3 times
Flash 4 times
Flash 5 times
Flash 6 times
Flash 7 times
Flash 8 times
Flash 9 times
Down
Reason for the Error
Abnormality of power
or controller
Abnormal motor
connection
Hall failure for motor
Short circuit or
overload of the motor
Rebound when it
encounters an
obstacle while moving
The desk top is not
horizontal (Reserved
function)
Reserved function
Reserved function
The motor has run
longer than 2 minutes
Solutions
Replace the power or
controller
Check or replace the
motor connection cable
Check or replace the
motor
Reduce the load weight
of desk top and restart
Rebound protection
alert, normal condition
Wait to use the motor
for 20 minutes
11

Publicidad

loading