Service instructions
Tightening of threaded connections
The tightening torques indicated in the exploded views list are established to achieve the
correct clamping force and preventing the parts from coming loose. At service these parts
must be able to open up without being destroyed. In special circumstances (depending on
application and usage) the parts may however come loose after some time of operation. In
such cases the torque could be increased 10-20% and if necessary some type of low or
medium threadlocking fluid could also be applied.
Example
Diagram, RE - signal
Air pressure (bar)
Clutch releases
6.3
Running down
Start
With the RE-signal Kit an air pressure signal will be supplied, which can be connected to
a control unit to count the number of tightening and to detect premature and rehits.
Check of valve position
+ 10-20% Nm
LOCTITE
Tightening
Time
Lever is released
6.7 ± 0.5 mm
Part no
Issue no
Series no
Date
Page
For adjustment:
Hold the rod and turn the plastic valve
Nominal length: 154 mm
2050531993
6
C
2019-10
53