Maintenance
Use the following procedures to keep your HVLP spray system
running properly.
cleaning / Replacing the Filters
IMPORTaNT: Make sure the turbine is unplugged before
changing the filters.
1. Remove the filter covers on each side of the turbine by
turning them counterclockwise.
Filter cover
2. Remove each filter set from the filter cover on each side of
the turbine.
Silencer foam
Screen
Filter
Filter cover
3. Clean the filters. Either tap the filters to knock out the
contaminants or use pressurized air to blow out the
contaminants. For material that is not blown or knocked
loose easily, soak the filters in soapy water or mineral
spirits. Allow the filters to dry completely before placing
them back in the turbine.
NOTE: Do not use highly flammable solvents, such as
lacquer thinner, to clean the filters.
4. Insert each filter back into its corresponding filter can.
5. Replace the filter covers on each side of the turbine by
turning them clockwise.
After several cleanings, it may become necessary to replace the
filters. Refer to the parts list near the end of this manual for the
filter replacement kit part number.
English
Filter cover
Filter
Screen
Silencer foam
cleaning the air hoses
1. Periodically wipe the outer surface of the air hose with a
damp cloth to keep clean.
IMPORTaNT: DO NOT submerge into or flush the air hose
with water or any chemical.
IMPORTaNT: DO NOT use methylethylketon (MEk),
naphtha, mineral spirits, paint thinner, xylol/xylene, or toluel/
toluene to clean the air hose. Exposure over time could
cause damage to the hose.
IMPORTaNT: Store indoors with the cord wrapped around
the handle.
4
© Titan Tool Inc. All rights reserved.