B. OUTSIDE TOP EXHAUST (VERTICAL DUCT)
INSTALLATION OVERVIEW
Bi. Attach mounting plate to wall
B2. Prepare top cabinet
B3. Adjust blower
B4. Check damper operation
B5. Mount microwave oven
Bé. Adjust exhaust adaptor
B7
Connect ductwork
B1. Attach the mounting plate to the
wall
Attach the plate to the wall using toggle bolts. At least
one wood screw must be used to attach the plate to a
wail stud.
1. Remove the toggle wings from the bolts.
2. Insert the bolts into the mounting plate through the
holes designated to go into drywall and reattach the
toggle wings to 34" onto each bolt.
To use toggle bolts:
Spacing for Toggles More Than
Wall Thickness
i Toggle Wings
Mounting
|:
joa
Plate
aay:
ix
Bolt
-—1\
ly
co
"1 Bolt End
14
3. Place the mounting plate against the wall and insert
the toggle wings into the holes in the wall to mount
the plate.
NOTE: Before tightening toggle bolts and wood
screw, make sure to line up bottom line of the
Mounting plate with Horizontal line of "Rear wall
Template' and then the Mounting plate is properly
centered under the cabinet.
CAUTION: Be careful to avoid pinching fingers
between the back of the mounting plate and the wall.
4. Tighten all bolts. Pull the plate away from the wall to
help tighten the bolts.
B2. Use top cabinet template for
You need to drill holes for the top support screws and
a hole large enough for the power cord to fit through.
*
Read the instructions on the TOP CABINET
TEMPLATE.
*
Tape it underneath the top cabinet.
*
Drill the holes, following the instructions on the
TOP CABINET TEMPLATE.
CAUTION: Wear safety goggles when drilling holes in
the cabinet bottom.